fbpx

Panasonic 1.5HP Standard Non-Inverter R32 Air Conditioner CS-PN12WKH

CS-PN12WKH

  • Horse Power – 1.0HP
  • Cooling Capacity – 9,500 Btu/h
  • Comfort Technology – R32 Refrigerant, BIG FLAP
  • Standard Non-Inverter
  • R32 Refrigerant
  • BIG FLAP
  • Up to 18% Faster Cooling
  • 3 Starts Energy Rating
PAN-CS-PN12WKH ,

RM1,575.00

Split your payment & pay RM472.50 today myIOU

In stock

Support
FEATURES

  • Standard Non-Inverter
  • R32 Refrigerant
  • BIG FLAP
  • Up to 18% Faster Cooling
  • 3 Starts Energy Rating

OVERVIEW

SPECIFICATIONS

Model

  • Indoor (50Hz) : CS-PN12WKH-1
  • Outdoor (50Hz) : CU-PN12WKH-1
  • Refrigerant Type : R32

Cooling Capacity

  • (min-max) kW : 3.52
  • (min-max)Btu/h : 12,000

EER

  • (min-max) Btu/hW  : 11.21
  • (min-max) W/W : 3.29
  • CSPF : 3.43

Electrical Data

  • Voltage (V) : 230
  • Running Current (A) : 4.8
  • Power Input (W) : 1,070

Moisture Removal

  • L/h : 2.0
  • Pt/h : 4.2

Air Circulation

  • Indoor m³/min (ft³/min) : 11.6 (406)
  • Outdoor m³/min (ft³/min) : 29.8 (1,050)

Noise Level

  • Indoor (H/L/Q-Lo) (dB-A) : 41/29
  • Outdoor (H / L) (dB-A) : 51

Dimensions

  • Height (mm) : 290 (542)
  • Height (inch) : 11-7/16 (21-11/32)
  • Width (mm) : 779 (780)
  • Width (inch) : 30-11/16 (30-23/32)
  • Depth (mm) : 209 (289)
  • Depth (inch) : 8-1/4 (11-13/32)

Net Weight

  • Indoor kg (lb) : 8 (18)
  • Outdoor kg (lb) : 26 (57)

Refrigerant Pipe Diameter

  • Liquid Side (mm) : ø 6.35
  • Liquid Side (inch) : ¼
  • Gas Side (mm) : ø 9.52
  • Gas Side (inch) : 3/8

Pipe Extension

  • Chargeless Pipe Length (m) : 7.5
  • Maximum Pipe Length (m) : 20
  • Maximum Elevation Length (m) : 15
  • Additional Refrigerant Gas* (g/m) : 10
  • Power Supply : Indoor

Cleaner Air

  • nanoe™X : No
  • nanoe-G : No
  • Anti-Dust Coating : No
  • Dust Sensor : No
  • Odour-Removing Function : Yes
  • Removable, Washable Panel : Yes

Comfort

  • Radiant Cooling : No
  • iAUTO-X : No
  • iAUTO : No
  • ECONAVI : No
  • ECO Mode with A.I. : No
  • Temperature Wave : No
  • SLEEP : Yes
  • Inverter Control : No
  • Powerful Mode : Yes
  • Quiet Mode : Yes
  • Soft Dry Operation Mode : Yes
  • Personal Airflow Creation : No
  • Airflow Direction Control (Up Down) : Yes
  • Manual Horizontal Airflow Direction Control : Yes

Convenience

  • 24-Hour Dual ON OFF Real Setting Timer : No
  • 24-Hour ON OFF Real Setting Timer : Yes
  • LCD Wireless Remote Control : Yes
  • Wireless LAN Remote Control For Internet Connection : No
  • Wired Remote Control : Yes (Optional)

Reliability

  • Random Auto Restart (32 Restart Patterns) : Yes
  • Blue Fin Condenser : Yes
  • Long Piping (Numbers indicate the maximum pipe length) : 20m
  • Top-Panel Maintenance Access : Yes
  • Self-Diagnostic Function : No

NOTE

Please do not use copper pipes that are less than 0.6mm in thickness.

*When pipes are not extended from the standard pipe length, the required amount of refrigerant is already in the unit.

Brand

PANASONIC

QR Code

QR Code
Preview
Close
Open chat
1
Thank you for contacting Marketing Suria Jerai! Please let us know how we can help you.
We will reply you as soon as possible. Thank you.

*Be Our MEMBER & Enjoy FREE SHIPPING!

Working Hours : 9.00AM to 6.00PM (Saturday until Thursday)
Closed : Friday & Public Holiday

Shopping cart

close